OCTG Thread Working Gauges play a vital role in fields such as oil extraction. Ensuring their normal performance is the key to ensuring the quality of oil well pipe connection and safe production. The following are some methods to detect whether the performance of OCTG Thread Working Gauges is normal.

First, you can make a preliminary judgment through visual inspection. Check whether there are obvious scratches, deformation or corrosion on the surface of the working gauge. If these problems exist, it may affect its measurement accuracy and service life. At the same time, check whether the threaded part is intact and whether there are signs of damage or wear.

Secondly, perform dimensional measurement. Use high-precision measuring tools such as micrometers and calipers to measure the key dimensions of the working gauge, including the major diameter, minor diameter, and pitch of the thread. Compare the measurement results with the standard size. If the deviation is within the allowable range, it means that the dimensional accuracy of the working gauge is normal.

Furthermore, perform actual measurement comparison. Select an oil well pipe thread specimen with a known standard size and measure it with a working gauge. Then compare the measurement results with the standard size of the test piece. If the two are highly consistent, it means that the measurement accuracy of the working gauge is reliable. At the same time, different working gauges can be used to measure the same test piece and compare the consistency of the measurement results to further verify its performance.

In addition, check the identification and certificate of the working gauge. A formal working gauge should have a clear identification, including information such as model, specification, and accuracy grade. At the same time, it should be accompanied by a corresponding test certificate to prove that it has undergone strict quality inspection.

Finally, calibrate regularly. Send the working gauge to a professional metrology and testing agency for calibration, and judge whether its performance is normal based on the calibration results. The calibration cycle should be determined according to the frequency and importance of the use of the working gauge.

In short, through visual inspection, size measurement, actual measurement comparison, inspection of identification and certificate, and regular calibration, the performance of OCTG Thread Working Gauges can be effectively detected to ensure that it plays an accurate and reliable measurement role in oil well pipe connection.
×